Product Name: | 50mm Water Oil Electromagnetic Flow Meter For Liquid Nitrogen | Medium: | Sewage, Water, Conductive Liquid |
---|---|---|---|
Power Supply: | 220VAC/24VDC/Battery | Output: | 4-20mA /4-20mA + Hart |
Material: | 316L, Ti, Pt, Etc. | Brand Name: | Vacorda |
High Light: | electromagnetic water flow meter,electromagnetic flow sensor |
50mm Water Oil Electromagnetic Flow Meter For Liquid Nitrogen
HKLD type intelligent electromagnetic flowmeter is a fully intelligent electromagnetic flowmeter developed by our company using the most advanced technology at home and abroad. Its electromagnetic converter core adopts high-speed central processing unit. The calculation speed is very fast, the precision is high, and the measurement performance is reliable.
Features
1. There are no flowing and blocked flow parts in the pipeline of the 50mm water oil electromagnetic flow meter, and there is almost no additional pressure loss in the measurement.
2. The measurement result of the 50mm water oil electromagnetic flow meter has nothing to do with physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.
3. The electromagnetic flowmeter uses a fast, high-precision 16-bit embedded processor to enhance the measurement stability.
4. The 50mm water oil electromagnetic flow meter has anti-interference and high reliability, and the measurement range is up to 150: 1.
5. The flowmeter adopts ultra-low EMI switch, and the power supply voltage range is wide.
Product Parameters
Product Name | Electromagnetic Flowmeter |
Repeatability error | +/-0.1% |
Accuracy class | 0.5 class, 1.0 class |
Measured medium temperature | Common rubber lining: -20~+60 ° c |
High temperature rubber lining: -20~+90 ° c | |
PTFE lining: -30~+100 ° c | |
High temperature vinyl lining: -30~+180 ° c | |
Rated working pressure | pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa; |
Flow rate range | 0.3~15m/s |
Measured fluid conductivity | ≥5μs/cm liquid |
Output | 4~20mA / 4~20mA + Hart |
Electrode material | 316L, titanium (Ti), tantalum (Ta), Hastelloy (H), |
Working power supply | 85~265VAC / 24VDC / Battery |
Straight pipe length | pipe: ≥ 5DN in the upper reaches, downstream of |
Connections | Flange |
Protection grade | standard: IP65; IP68(optional) |
Explosion-proof mark | mdllBT4 |
Application